We’re here to keep your power on, 24/7/365

Authorized factory trained certified technicians. Servicing generators up to 2MW generator.

Scheduled Maintenance Performed by Your Generac Industrial Factory Authorized Team

  • Annual
  • Semi-Annual
  • Quarterly
  • NFPA 110 Life Safety

Need service? We make it easy, just complete the form below!

Service Form - GENRG POWER

5 + 3 =

The Right Choice

Our team consists of professionals who have proven reliable, both in terms of manufacturing training and industry experience. We are a trusted company readily available 24/7/365.

Scheduled Maintenance Plans

  • Annual
    • (1) Full-Service Check
  • Semi-Annual
    • (1) Full-Service Check
    • (1) Inspection Check
  • Quarterly
    • (1) Full-Service Check
    • (3) Inspection Checks
  • NFPA 110 PER JURISDICTIONAL CODE

Standard Generator
Scheduled Maintenance

Scope of Service Checks

Full-Service Check

  • Replace engine lubricating oil and dispose of it environmentally responsibly.
  • Replace oil filter(s) in natural gas engines.
  • Replace oil and fuel filters in diesel engines and coolant filter if required.
  • Inspect air filter(s) and crankcase breathers. Replace (additional cost) with client’s approval.
  • Inspect the cooling system for leaks and conditions.
  • Inspect and adjust belts as required.
  • Natural gas/LPG fueled engines inspect spark plug wires and ignition system for damages and excessive wear.
  • Inspect the generator fuel system for leaks or damage.
  • Inspect wiring and connectors.
  • Inspect battery(s) condition (load test) electrolyte levels, check for corrosion and battery charger function.
  • Run the engine and check temperatures and pressures.
  • Test the governor for proper operation and stability and inspect linkage.
  • Test the engine safety shutdown systems.
  • Test system for proper frequency/speed, voltage, and amperage.
  • Inspect the transfer switch and perform the transfer with the client’s approval.
  • Submit a written report to the client and advise of any further work required.

Inspection Check

  • Inspect engine lubricating oil and coolant for proper levels and condition.
  • Inspect air filter(s) and crankcase breathers. Replace (additional cost) with the client’s approval.
  • Inspect the cooling system for leaks and conditions.
  • Inspect and adjust belts as required.
  • Natural gas/LPG fueled engines inspect spark plug wires and ignition system for damages and excessive wear.
  • Inspect the generator fuel system for leaks or damage.
  • Inspect wiring and connectors.
  • Inspect battery(s) condition (load test) electrolyte levels, check for corrosion and battery charger function.
  • Run the engine and check temperatures and pressures.
  • Test the governor for proper operation and stability and inspect linkage.
  • Test the engine safety shutdown systems.
  • Test the system for proper frequency/speed, voltage and amperage.
  • Inspect the transfer switch and perform the transfer with the client’s approval.
  • Submit a written report and advise the client of any further work required.

Houston, TX

Largest Water Plant in the USA

Need: Emergency Standby Generator to back up utility on large surface water pumps.

Solution: A Generac 1500kw Diesel Generator with Level II Sound Enclosure. Generators of Houston sold the unit and assembled the Level II sound ‘Wings’ on site. We performed Factory Startup with 4 hour load bank and a 4-hour Customer Orientation of the System.

Contact us today to schedule maintenance on your INDUSTRIAL generator